Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1)Why electric shock is feel ?? n in a Electric Train why
we didnt feel that ?

2)What is the reason for transformer Noise ??

3)What is relation b/w Transmission Lines & Communication
Lines ?

4)Which material is used for making Transformer oil & How u
measure its dielectric strength & Name the test ?





Answer Posted / rajkumarsripelli

ya....this is rajkumarsripelli Testing engineer trasformer
division...

Kaarthikrt&c09894209497 said that due to corona loss is
dead wrong..for 2nd answer

2:ans: the noice will be getting from loaded transfomer is
due to the mechanical vibration of the core...in detail...
for making of transfomer as we know that we will be using
silicon steel core material...so this core is assembled in
proper way..as per the standareds...when we apply the
voltages through the windings to this core the core will be
magnetised...due to this high voltages the core will
vibrates when its magnetised....and the vasavi said above
may be correct...........



thanks..

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between type1 and type2 relay protection co-ordination for motor feeders

2284


Why do we avoid electrical conduits in floors at apartments?

2129


What is the Surge suppresor? Why using in a UDB's and How it works?

2243


How to Make relay co ordination chart for a Electrical power distribution of a plant

3891


What is superposition theorem?

1241


how to flameproof electrical motor on the shaft?

2127


quantizer means?

1990


what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

2319


Why need 3phase machine double earthing?

1829


If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.

1935


3ph motor running with unequal kw and different pf what are the reasons

1962


What is the formula to find out two phase active & reactive power

2231


Can anybody tell abt concrete encased earthing or grounding?

2118


how we can set the IDMT relay.

2266


why connecting surge unit in contactor coil

1931