hi all plz tell me difrence between analog or digital load
cell.
Answer Posted / santosh gawande
in digital loadcell the a/d converter ( bridge amplifier is
near to the strangauges so signal op is correct
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.
What is the diffrence between ff tx and non ff tx
Coal mill Instruments Equipments for cement plant And process diagram ?
Calibration procedure for electro magnetic flow meter
sir, give me placement papers and interview quistion of birla group company of copper.
Why mmwc unit is used?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
How to Calibrate Level Switch in field
How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?
What are different types of control valves?
How would you choose differential range?
what is the reset offset and control system in instrumentation
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
In a gas over oil actuator, after the opening/closing of valve, how the gas is vented out? How does the hydraulic/gas circuit function?