Describe your experience with analytical instrumentation?

Answer Posted / swati

At present working as Laboratory Executive in application &
Wet laboratory, working on AAS, GC, HPLC,
Spectrophotometer for the analysis of Soil, Air, water
(Ground, Surface, Sewage, Industrial effluents) as well as
pharmaceutical product. And report submission of samples.


• Work on multitudes of aspects in the lab apart from
analysis.

• Analysis of Volatile Organic Carbons, PCB’s, PAH,
Phenols, CO, CO2 using methanizer,
FAME analysis .
• Developed a perfect hand in utilization, handling
and maintenance of GC (All netel
manufacturing ), HPLC (Water TM 486),AAS
(PerkinElmer),UV-VIS
Spectrophotometer.(Thermo-Orion)
• Having a Knowledge of making S.S. Columns and
method development.

1.Analysis of Different Types of Raw Material, Tablets,
Syrup, Perfume, Injections, Oils etc.

Worked On :
 Gas Chromatography (MACRO 9100, Ultima-2100,
Analyte-2700, Platina, (All Netal GC)
 HPLC - Saif Water HPLC (Double Piston Pump)
 Water TM 486 Tunable absorbance Detector (Single
Piston Pump)
 IR: FTIR -410 Jasco

2.Gas Chromatography:
 Separation Of components from mixture using CHEMITO
8310 Gas Chromatograph
3.Spectrophotometer Mtd. Of s analysis:
 U.V. Visible Spectrophotometer (ELICO INDIA SL-
159), Visible Spectrophotometer (ELICO INDIA SL-171,
Colorimeter (ELICO INDIA), Polarometer, Nephelometer,
Florometer, Flame Photometer etc.
4.Industrial Chemical Analysis:
 Volumetric Analysis: Acidimetric, Alkalimetry, PPT,
Redox, Complexometric, Estimation of Industrial Chemical,
Ores, Minerals, Alloys & Oils etc.
 Physico Chemical Analysis: PH Meter, Conductometer,
electrolytic analyzer, Refractometer, Say Bolt
 Viscometer & EC-TDS Meter etc.

Is This Answer Correct ?    22 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

351


Explain the relations between number of carbon atoms in alkanes and retention time ?

1622


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1141


What is related substance by HPLC impurity limits as per USP?

553


what is definition of validation? which components are followed give detail?

1827






what is the difference between potentiometric titration and karl fischer titration?

2416


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2219


how you determine moist.of NaOH sol or NaOH flacks

1768


How we choose the mobile phase for method development.?

651


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1245


analytical method validation require to with respect to release specification or shelf life specification?

278


How to determine water content of bis tetrazole amine mono ammonium salt

2960


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

1935


what is turbidimetric titration?Give 2 examples.

1985


What is delay volume?

845