Describe your experience with analytical instrumentation?
Answer Posted / swati
At present working as Laboratory Executive in application &
Wet laboratory, working on AAS, GC, HPLC,
Spectrophotometer for the analysis of Soil, Air, water
(Ground, Surface, Sewage, Industrial effluents) as well as
pharmaceutical product. And report submission of samples.
• Work on multitudes of aspects in the lab apart from
analysis.
• Analysis of Volatile Organic Carbons, PCB’s, PAH,
Phenols, CO, CO2 using methanizer,
FAME analysis .
• Developed a perfect hand in utilization, handling
and maintenance of GC (All netel
manufacturing ), HPLC (Water TM 486),AAS
(PerkinElmer),UV-VIS
Spectrophotometer.(Thermo-Orion)
• Having a Knowledge of making S.S. Columns and
method development.
1.Analysis of Different Types of Raw Material, Tablets,
Syrup, Perfume, Injections, Oils etc.
Worked On :
 Gas Chromatography (MACRO 9100, Ultima-2100,
Analyte-2700, Platina, (All Netal GC)
 HPLC - Saif Water HPLC (Double Piston Pump)
 Water TM 486 Tunable absorbance Detector (Single
Piston Pump)
 IR: FTIR -410 Jasco
2.Gas Chromatography:
 Separation Of components from mixture using CHEMITO
8310 Gas Chromatograph
3.Spectrophotometer Mtd. Of s analysis:
 U.V. Visible Spectrophotometer (ELICO INDIA SL-
159), Visible Spectrophotometer (ELICO INDIA SL-171,
Colorimeter (ELICO INDIA), Polarometer, Nephelometer,
Florometer, Flame Photometer etc.
4.Industrial Chemical Analysis:
 Volumetric Analysis: Acidimetric, Alkalimetry, PPT,
Redox, Complexometric, Estimation of Industrial Chemical,
Ores, Minerals, Alloys & Oils etc.
 Physico Chemical Analysis: PH Meter, Conductometer,
electrolytic analyzer, Refractometer, Say Bolt
 Viscometer & EC-TDS Meter etc.
Is This Answer Correct ? | 22 Yes | 7 No |
Post New Answer View All Answers
If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately
Explain the relations between number of carbon atoms in alkanes and retention time ?
What if impurity area in control sample coming more as compared to LOQ level of impurity ?
What is related substance by HPLC impurity limits as per USP?
what is definition of validation? which components are followed give detail?
what is the difference between potentiometric titration and karl fischer titration?
what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me
how you determine moist.of NaOH sol or NaOH flacks
How we choose the mobile phase for method development.?
For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?
analytical method validation require to with respect to release specification or shelf life specification?
How to determine water content of bis tetrazole amine mono ammonium salt
in gas chromatography what is the difference between gas flow rate and average linear velocity ?
what is turbidimetric titration?Give 2 examples.
What is delay volume?