WHY WE CAN GENERATE POWER IN 3PHASE MODE ONLY NOT IN 4 OR 5
PHASE?
Answer Posted / bmw6633@gmail.com
it is easy for compatability ,not more risk involved and the
3phase will generate 440v.
| Is This Answer Correct ? | 0 Yes | 10 No |
Post New Answer View All Answers
sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me
how to calculate maximum current
i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.
What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
Why the unit sizes of hydro generating machines are not standardized as in case of thermal powerplants?
What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker
how we calculate the dick for a pole?
What is the basic of DTH.
sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)
What is the most important precaution in any experiment with d.c. Shunt motor?
For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?
typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
IF HT CAPACITOR IN ON POSITION IS THERE ANY LOSSES I.S I SQURE OCCURS IN THE SYSTEM