Is pure capacitor load and pure inductor load is an linear
load? pls justify
Answer Posted / rengan
capacitor load and inductor loads are non linear loads.
These loads works under ac supply.ac supply is alternating
quantity,not a constant.
so linear is impossible
| Is This Answer Correct ? | 4 Yes | 15 No |
Post New Answer View All Answers
why need to be maintain power factor for industrial customer?
how to build a network which step down 415v to 1v rms
Can we use both Electrical & mechanical interlock between tow breakers? if yes how, please explain
1. what is usage for power factor in industries?? 2.why we need to monitor power factor??
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
what is package substation.how many types they have
How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.
What is phase cross over frequency?
Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?
Diagram and details of polarity test for Current Transformer 11kv 400/200/100/1A
what is the function of Moulded case circuit breaker, why it is called Moulded?
CT Ratio of a energy meter connection is Red Phase : 100/5A, yello Phase : 50/5A & Blue phase : 100/5 A what is the overall Multiplication factor
How to reduce -234126219.6403 MVAr generation and by what?
Is potential difference materials property ..? if yes tnen how.. explain brifly.
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?