How can i modify the design of 3 phase induction motor to
be as 3 phase synchronous motor??
Answer Posted / raja
(1) U can remove the rotor of the 3 phase induction motor
and put the armature of the DC motor.
(2) supply DC suppy through the slip ring of the 3 phase
slip ring induction motor
| Is This Answer Correct ? | 2 Yes | 6 No |
Post New Answer View All Answers
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
Transmission voltage is kept 11KV,33KV,66KV,132KV,220KV due to form factor. What happen to 400KV and 765KV transmission voltage?
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
in indoor type circuit breakers why only the corner breaker trips specially during cold season. What is the reason.
Given a collection of points P in the plane, a 1-set is a point in P that can be separated from the rest by a line; i.e. the point lies on one side of the line while the others lie on the other side. The number of 1-sets of P is denoted by n1(P). The maximum value of n1(P) over all configurations P of 19 points in the plane is 18
What is kvar?
BRIEFLY EXPLAIN THE STORAGE CLASSES AND THEIR TYPES IN C
what are the Alarm, Trip & Safety equipment (Issues) present in Power Transformers pls Mail it to ashokbabunhce@gmail.com
What happens if we connect a single phase energy meter in reverse polarity.
Can we convert off line transformer to on line transformer
what is the solution for meger test failed the MV cable?
what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?
Can anyone please provide me details of MCCB/Contactor/SFU rating calculations for a motor feeder..for example 50 kw.. not from type-2 cordination chart. i want manual calculations..
What is the most accurate way of testing ELCB?ELCB is better than RCD?
WHY SEPARATELY EXCITED MACHINE NEEDS EXCITATION BY DC SUPPLY WHY NOT BY AC