some practicle study shows that the reactive power at the
receiving end is not equal to the reactive power at the
sending end.But according to theory the reactive power is
exchanged by different parts of the network – capacitors
and reactors permanently, but is never consumed or produced.
Then Where that reacrtive power loss occuring?is there any
formula to calculate reactive power loss?
Answer Posted / deepak
mahesh i am not asking about active power loss i am asking
abt reactive power loss when we say that reactive elements
never consume any energy then y reactive power at the
receiving end is not equal to the reactive power at the
sending end
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How one can check the MAIN of a house wiring ?
What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
If one lamp connects between two phases it will glow or not?
list the advantages of RCCB over other circuit breakers?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
What is difference between slip rings and carbon burushes?
Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.
If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)
What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?
If UG power cable both ends are to be earthed or what? If not why?
what is the min and max ohmic resistance for the earthing rod installed for lighting poles for street light network
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
State the types of distortions in amplifier?
Define resonant peak?