PID controller is used for which type of compensation……
a) lead comp. b) lag com. c) lead lag com.
Answer Posted / dileep mishra
PID - Proportional integral & derivative
control modes of PID
1) on\off control
2) proportional control
3) proportional integral control
4) proportional derivative control
5) proportional integral & derivative control
| Is This Answer Correct ? | 13 Yes | 27 No |
Post New Answer View All Answers
please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com
we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks
hello can yoy pls send me previous papers of jindalpower and steel ltd.....'m from instrumentation..... mani1048@gmail.com
can you send remote seal interface level transmitter calculation steps for oil water saperator.
what is the protection system in solar turbine compressor
How r the calculation of process line mpm.
In which principles tx ,pressure gauge,Temp gauge,control valve works?
what are the different types of Protocols? & their applications.
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove
List three types Level Switches with their working principles
What are the application of bernoulli’s theorem?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
How u measure the massflow in orifice flow measurement techniques