What is diffrence between Transducer and Transmitter?
Answer Posted / chandrasekar
Transducer is a device which converts on form of energy to
other form of energy.simply from non-Electric quantity
(pressure, temperature etc) to an electric quantity(voltage
or current)
Transmitter is a device which helps to convert a signal(may
be electrical or non-Electrical) into a form suitable for
transmission over a large distance.
Is This Answer Correct ? | 13 Yes | 5 No |
Post New Answer View All Answers
How we calculate orifice plat size???
Draw block digram for well head from well to shipping pump?
Isometric drawings are generated during _________________ phase of a project
how do u calibrate the vacuum transmitter if it shows more reading
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
How to Calibrate Vortex Flow transmitter in field
How to Calibrate Interface Level Troll in field
What is the procedure of calibration of Load cell?
In VVVF DRIVES VOLTAGE IS ALSO VARY WITH THE FREQUENCY. HOW? WHAT IS THE DIRECT FORMULA RELATING THESE TWO.
what effects a surging can produce in the compressor
In Safe Guarding test what means by "Failed to Danger" ?
what is the input of digital counter during the the calibration time?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
how works encoder in plc
a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error