Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the minimum distance between substation wall and LT
panel outer surface?

Answer Posted / niti

750mm

Is This Answer Correct ?    28 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we use Test Terminal Block in 11 KV and 33 KV electrical panels.

1375


how to introduce yourself

2034


why are u join ntpc

2161


for what purpose the star point is done in ct

1416


what will happen if earth of 33 kv cable (earthed system) is not connected to earthing pit?

2030


For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?

1973


what is the use of current transformer in power transformer secondary side.?its connectyed in WTI

1727


In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

2123


if flux and load static in dc motor and supply voltage increases 20% then what happened in speed

1905


Why delta star trformers are used for lighting loads?

1177


working principles of cf lamp,incandescentlamp and f lamp?

2252


Can anybody please refer the best and simple book for about Protection relays and in detail of all its protection ?

1977


Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.

1986


FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?

3401


Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?

1802