Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

As we know,charged clouds(from which lightning stroke
initiates)may be charged with either +ve charge or -ve
charge.
Now say one cluster of cloude is fully charged with +ve
charge & another cluster is fully charged with -ve charge.
In the sky these two cluster of charged clouds have come in
such a distance that, if they come clouser by some few
yeards then the lightning discharge will take place between
these two cluster of clouds. Under such a situation an
Aircraft came inbetween. what happend??

Answer Posted / shinyvikram ganji

ACTUALLY THERE ARE MANY THEORIES REGARDING LIGHTNING STROKE.
EACH HAS ITS OWN WAY.
SOME THEORIES SPECIFES ABOUT THE GROUNDING CONDITION.SO
FOR A LIGHTNING STOKE GROUNG MUST BE COMPULSORY.OTHER WISE
THERE IS NO CLOSED PATH FOR THE LIGHTNING CURRENT.
SO WHENEVER PLANE COMES IN BETWEEN THERE IS NO GROUND,
HENCE PLANE WILL NOT BE AFFECTED.

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured

1524


Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

4262


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1811


Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings

2024


pls tell me function of closing coil of A.C.B.

3323


what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator

1986


which pump used in STP

2153


What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439

969


what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

18378


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

1868


If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.

2050


What are the classifications of oscillators?

1038


How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2098


What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?

2225


How grounding is different than earthings?

1117