1KVA transformer of different frequencies of
50hz,100hz,500hz&1000hz. which one of these transformer has
big size? Give reason
Answer Posted / ambi
this is a short cut method based on analysis..
generally power transformers use lower frequncy(50hz) and
we know in electronic ckts like oscillators producing very
high frqs in range of KHz we use only SMALL trfrs than pwr
trfrs.... so on analysing we can conclude tat higher
frquency transformers have less volume...
NOTE: this is only shrt cut mthd, actual reason depends on
the FORMULA only for determining the size
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
does any one know where we can purchase insulation oil for high voltage oil filled cables
If ROC does not lies inside unit circle,then ? a) Fourier transform converges b) Z transform converges c) Hatly transform converges d) Colpit Transform converges.
what happen if drive input fail momentry at 48.5 HZ frequency?
can i use 2000/5A Clamp meter to measure HT cable
Explain few advantages of electric traction system?
Can we check ELCB constantly from R1 to R8 phase in 1 no DB?
why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?
What type of wiring series or parallel is used for conventional and addressable type FAS & why?
What is vacuum circuit breaker.define with cause and where be use it device?
What is NGR . What is the purpose of 10 sec ,60 sec rating of NGR.
dear sir, i completed diploma in electrical in 2005, how i can get electrical supervisor liance in mumbai
ELECTRICAL ENGINEER TEST IN FEWA ANY ONE HAVE KNOWLEDGE ABOUT THIS?????????
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
difference between main metering kiosk and check metering kiosk
I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing