Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how LVDT works?

Answer Posted / md ahmeduddin farooqi

The linear variable differential transducer (LVDT) is a type
of electrical transformer used for measuring linear
displacement. The transformer has three solenoidal coils
placed end-to-end around a tube. The centre coil is the
primary, and the two outer coils are the secondaries. A
cylindrical ferromagnetic core, attached to the object whose
position is to be measured, slides along the axis of the tube.

An alternating current is driven through the primary,
causing a voltage to be induced in each secondary
proportional to its mutual inductance with the primary. The
frequency is usually in the range 1 to 10 kHz.

As the core moves, these mutual inductances change, causing
the voltages induced in the secondaries to change. The coils
are connected in reverse series, so that the output voltage
is the difference (hence "differential") between the two
secondary voltages. When the core is in its central
position, equidistant between the two secondaries, equal but
opposite voltages are induced in these two coils, so the
output voltage is zero.

When the core is displaced in one direction, the voltage in
one coil increases as the other decreases, causing the
output voltage to increase from zero to a maximum.

LVDTs are commonly used for position feedback in
servomechanisms, and for automated measurement in machine
tools and many other industrial and scientific applications

Is This Answer Correct ?    12 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the difference between PLC and embedded

2186


Explain what is rated speed?

1193


please send previous exams question papers

1870


which type of stability limit is higher,steady state or transient? why?

1946


how many stairs have you climbed while you were coming

2226


describe the A.C. Generator Testing procedure

2220


What happens to a motor if it is connected in Delta connection

1105


A ray hit a smooth regular surface at an angle of 20 from the normal. Calculate : 1. The angle btw the incident and reflection ray. 2. The angle of deviation.

1983


what is the size of cable for 15kw motor and 85 meter cable length using with vfd

2425


What is kirchoff ’s current law (kcl)?

1133


Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?

2124


WITCH CARDS IN USE IN FIRE CONTROL PANEL.

1969


Different STANDARDS (BS, IS, IEC etc) gives different informations on CT specification. How they correspons w r t each other (i.e I mean to say BS provides "knee point voltage" but IS does not, then how can i select CT)

2008


What fomula is used to calculate: 1. rated frequency withstand voltage, and 2. rated lightning impulse withstand voltage.

1768


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

2019