Name different types of fault and which instrument is used
to measures earth,short,open cicuit fault?

Answer Posted / monalisa rout

unsymmetrical faults,symmetrical faults,ground-to-
ground,line to ground ,nline to line and megger is a unit
to measure it.

Is This Answer Correct ?    6 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2121


please send 5yearje solved papers on my email himmatsinghnathawat@gmail.com

1471


do you have some of interview Questions in power and genrator section in general whith answers

1640


What is MSL designation of a motor and same may be provided in details.

1224


why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??

1879






what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated

1516


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

1852


what is KSR type transmission tower? What is LSR type transmission tower?

4629


how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?

1619


how i can calculate the size for fire cable

1495


what is cascade speed control device?and how this device control the speed of motors?

1551


please send previous exams question papers

1389


How REF protects transformer alone? explain with diagram.

1010


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1655


What does Bode plot tell you?

805