why most of the substations are rated in multiples of 11?

Answer Posted / abduljameel

it is not multiples of 11.It is multiple of 1.11.This is
because of form factor for a sinusoidal curve is 1.11.

Is This Answer Correct ?    22 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

1723


When distance between two pulleys is not fixed, the tension of belt is adjusted by a) driver shaft b) driven shaft c) adjustment screw d) belt

2441


Haw to check conductivity of budbar

1345


hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused

1550


what is a power factor?

1325






If I have 3 essential main switch board and 3 incoming electricity ,but only 1 genset running is that possible.

1146


Sir, plz tell me how droop setting is done in parellel operation od DG set ? please give practical example ?

1683


defult setting in p220 micom motor proction relay for 11kv,640kw,f.l.a.-40a,1440rpm ht motor?

3226


what is high and low cut off voltage of BB and DG at SPS????????

1007


iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.

1764


Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?

2486


why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)

2008


How isolater function when installed inelectrical 440V wiring

1708


When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?

1364


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.

1143