why aggregate is placed all around substation ground.
Answer Posted / samal
Ok grass can cause moisture ,it will help in maintaining
the resistance of yard(will be very low)
so moisture is not the reason of that cause.
it(aggregate) will mantain the capacitance of yard ground
to live part & helps in maintaining vibration
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
how we do Vector group ,magnetic balance and tap changer test in Transformer?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
why should the primary of transformer be connected in delta in a heat run test?
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
What are unstable systems?
how to erect roof control panel?
How to calculate the size of earth cable to earth the neutral of UPS ?
In dc ckt. 24v or 110v, which one is more efficient and why?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
WHAT IS THE FORMULA FOR CALCULATING CURRENT RATING(DIRECT IN GROUND OR AIR) OF ARMOURED(XLPE) CABLE OF 4C,16Sqmm?
What do you mean by passive circuit elements and why these are called passive?
How many double suspension hardware fittings are required on a double circuit transmission tower?
WHAT IS THE WINDING PROCEDURE OF ELECTRICAL MOTOR
our factory is going under construction mean time transformer 1000 kva 2 nos &load break swithch 12 kv & 4 nos 750 kva 2 nos & 380 kva 2 nos generator to be errcted.how to arrange earth pits &how to earth connect & neutral pit how to calculate in earth bit size.