Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how current flows in circuit?

Answer Posted / taufic

In a closed circiut

Is This Answer Correct ?    20 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

for what voltage will reactive power be largest in 380 kv line : a) 375kv b)380kv c)385kv

1529


what is the meaning of number in (11, 31, 61,14, etc. CDG11, CDG31, CDG61, DDT32

1489


Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?

1768


What is servo motor? what is its purpose?

2116


please send me latest & previous years question papers for IOCL Technical level questions

1925


george phenomenon of synchronous machine

7602


What is the difference between solid grounding and impedance grounding?

2186


I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?

2025


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1974


any application of back emf

2177


what is cogging and crawling

2595


In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.

1908


we are having 110 Kv,250mA Electrostatic precipitators for coal fired boilers. what will be static voltage and current after discharge and what time it will remain before earthing?

1967


what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth

1426


why normally Generator rating are between 11Kv to 22Kv?

4769