Answer Posted / gaurav srivastava
synchronous motor have 3 phase winding which is having
altarnating rotating nature and the rotor of motor have dc
wwindig which is connected to a dc source due to this the
rotar become magnetished thus there are two poles form in
rotar. that is South and North pole...since the stator
winding are 3phase so that the stator become magnetised but
it is change alternatively.....but there is main reason
that to zero starting is the alternating magnetisation is
very fast (in approx 1/20 sec)so that there is no pole
coupling in rotating stator field and rotor..so that is is
not self starting...
for this there is a prime mover is used to rotate it ..
by this there is magnet copling is formed so that it can
run...
there is main function of synchronous motor it always run
on synchronous speed..
MUST REED THIS/////
=>if motor start to run and there is a phase cut (one of
three)....it is not affect on the motor speed
GAURAV SRIVASTAVA (UNITED COLLEGE OF ENGINEERING AND
RESEARCH)ALLAHBAD
| Is This Answer Correct ? | 3 Yes | 3 No |
Post New Answer View All Answers
WHat is the requirement of installing FAST ACTING EARTH SWITCH in GIS and how is that integrated with protection system. How and when does it operate?
What does bode plots shows?
what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth
Why field rheostat is kept in minimum position?
How to check the cable fault / hv test of transformer cable.
What happens if we give the supply to the rotor of induction motor and make its terminal shorted?
What is an 86-P or an 86-A trip
what are the dimensions for 200 kva transformer plinth (plateform),in which pcc m20 is used..
what is a speed of rotor when we give supply to stator of 50hz and as well as rotor of 60hz of an induction motor?????
differnce between single acting and double acting solenoid valves
When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?
What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?
we can run 2phase as 3phase .what will be the differnce with respect to phase angle, power, current between the two modes
Give idea about General Engineering. From which book i can study this topic. Pl. reply me via email. My email is ravi@bhelhwr.co.in, also give the name of book/website, from where i can prepare it.
why we used ZNO in Lightning arrester.