Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by the KA-rating of a circuit breaker? In
this regard, discuss the stresses experienced by the
circuit breakers

Answer Posted / anand

KA Rating of Circuit Breaker is nothing but a Short Circuit
Breaking Current Capacity of Circuit Breakers which is
around 40 KA EHV Circuit Breaker.
The Circuit Breakers do experience Mechanical Stresses
during closing & opening operations.

Is This Answer Correct ?    28 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

132/66kv sub-station procation ?

2208


PLEASE SEND ME NTPC RELATED INFORMATION LIKE WHICH TOPICS HAV MORE SCOPE,BOOKS TO READ,CUT OFF...PLEASE.mail at thiru.1203@gmail.com

2043


Write the programming software name for LG, SIEMENS,Messung,AB

1975


What is creepage distance..... what will be the value for different voltage level

1925


Define unilateral circuit?

1158


What is given by the definition in BIL IMP/PF = 950/395 kV. This was found in a name plate of a power transformer.

2293


why is control bus bi-directional?

2104


why are installed water leakage detection system data centers & server rooms

2302


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

1981


importance of reactive power management

1974


What is the settings of distance protection relay in 400 kv line

1610


what work will do diffrential realay DG set

2824


some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?

1699


In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

2212


how can calculate 1kva generator running time in 1 liter keroscene

2558