which is batter in construction job,ELCB or RCCB?
Answer Posted / pravesh badoni
elcb as the name suggests earth leakage circuit breaker.
while rccb is residual current circuit breaker. any current
which remains in circuit disturbs the operation of machine
and is harmful for the ckt.rccb and elcb both are the same
thing which satisfies the purpose of disconnecting the
circuit when any residual or leakage current persists in
the circuit both are rated in milli ampers ranging in
fractions of ampere (30 ma to 80 ma).
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?
in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?
can anyone give an idea about dia calculation in cold rolling mill
While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?
what is dry and wet frequency withstand voltage? why & where it is used??
hey guys help me out.....what are the industrial uses/functions of nozzles in industries
what is star delta starter? how it works? give its control and power diagram.
3phase cable calculation formula by motor load
can u give me a brief idea about power line carrier communication ??
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
how will we calculate the copper wire load..
why 15 kw motor winding resistance is low then 5 kw motor winding resistance?
Explain bypass capacitor?