Why use the VCB at High Transmission System ? Why can't use
ACB? Pls explain the ans.
Answer Posted / rajesh dhankar
i'm sorry to say that above two answer give above are half
correct. because all u r talking about ionized air if u ever
open Chamber where CT's and PT's are connected u will find
distance less than a hand away and there is no problem of
ionized air there.
The main reason after that is at a time of breaking a ckt or
can say shutting down a ckt when load is not completely zero
there can be big damage or accident because of higher
voltage rather if load is completely zero then there is no
problem.
and ACB are used in low tension line where low voltage and
higher load can be controlled.
| Is This Answer Correct ? | 3 Yes | 5 No |
Post New Answer View All Answers
Salient pole alternator is more stable, why?
how much flux density of CRNO core
What is open loop and control loop systems?
What is bode plot?
HOW TO CALCULATE HV TEST VOLTAGE FOR ELECTRICAL EQPT.
The metal-enclosed switchgear and controlgear is subdivided into three types: 1. metal-clad switchgear and controlgear; 2. compartmented switchgear and controlgear 3. cubicle switchgear and controlgear. What is the main differnence between them. State some example.
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
im working in one private compeny in gujarat. i was complet diploma electric in 2010 from gujarat technical board. now i want electric supervisor licence in gujarat but i dont't know when i apply? plz give me address of the licence dippartment office in gujarat. gandhinagar
how to select electrical equipment such as fuse,dg,transformer,motor,msb,wire,cable as per the connecting load..please mention any books to design,take licence
how to select energy meter? have any calculation?
how electrical earthing maintenance done in industry?
in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly
What is PEC??Applications........
How does the slip regulator works as a startor
why swityard is necessrry requirement in any bis power distributin systems?