Answer Posted / anirban
From Bernoullie's theorem since the flow velocity increases
at the restriction(e.g. orifice) the pressure drops at that
location. As the reduced pr. equals the vapour pr. of the
liquid ,flowing through, vapor bubbles are formed. A sudden
expansion in the flow area after the restriction causes the
pr. to increase and the vapour bubbles collapse resulting in
erosion of pipe wall and generation of mechanical vibration.
This phenomenom is known CAVITATION.
| Is This Answer Correct ? | 10 Yes | 1 No |
Post New Answer View All Answers
what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?
How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)
What is the minimum rating availalbe for weld neck orifice in market?
What is the reason PT speed not incresed in gas turbine?
How to calibrate smoke Dectector
any questions on motor and energy conversions machines?
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?
how can i check vortex shedder bar it is ok? if there is ohms condition are shown correct?
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
What is the meaning of wet leg
How will you test a transistor with a multimeter?
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?
What is the diffrence between digital signal processing and discrete signal processing?