Answer Posted / azhar
cable size is calculated depending up on load ..for example
1 kw load takes 1.8 amps current..if the load is 5kw..than
9amp is the current for amp current the selection cable size
can be opted on the basis of manufature detial like
havells,polly cab..have the range of cable for certain
amount of current we have to selected the cable size on the
basis of manufacture range sheet
| Is This Answer Correct ? | 30 Yes | 10 No |
Post New Answer View All Answers
State magnitude criterion.
I want to do a mini project. Now I'm studying in 6th semis tor EEE Engineering.
how does an centrifugal and screw type chiller will work. which chiller efficiency is high and why.
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
what is per unit calculation?looking for simple and strong explanation thk u
The screw thread commonly used for transmission of motion is one of the following types of threads
what parameters should we check to reduce the power bill
How Self works in DG set
What do you mean by a current transformer?
How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?
I have two PLC processors. I want to communicate both processor with each other. How i can do so?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act
-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes