What is the power factor you maintain at ur organization?

Answer Posted / v.sureshkumar

i am maintain the power factor .85 to .9 in generation
plant.
power factor is ratio between the kva & kw ( active power &
reactive power) but basically in three typesof load is
there resistance load for lighting load that load is
maintain .95 to 1, inductive load based on induction
motor,incandesent lamp,welding transformer that load is
maintain .8 to .85 then over all power factor is
maintin .85 to .9 with additional load condition is
maintain apfc ( automatic power factor correction)capacitor
bank

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

1805


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1330


Will an earth leakage trip be activated if the component or wiring is faulty on low voltage equipment.Example An electrical Cat Scarer placed in the garden and water gets into the wiring.

1423


what is differentila pilot supervision in the incomer control panel in the power station?

1626


How to calculate KVA/VA rating of PT or CT from primary & secondary voltage or primary & secondary current?

1989






What is the difference between a fuse and a breaker?

613


tell me about eletrical contractor

1519


How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter

6700


Explain the working principle of Synchronous Generator and Assynchronous generator?

1734


what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?

2383


Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?

725


In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?

2776


why starting current is high and resistance is almost 0 during the starting of motor dc motor...?

1283


Define the term Capacitance and Inductance?

654


I have done my m.tech in electrical engg discipline. Can any one please suggest me how should I prepare for getting into phd in iit or nit.How should I prepare for getting into lecturership

1205