Do you know the overhauling of a motor?
Answer Posted / baker
WHEN THE MOTOR IS NOT IN GOOD CONDITION FOR EXAMPLE NOISE
OR HIGH VIBRATION... THEN THE CONDITION MOTORING INSPECTORS
WILL SEND THE MOTOR TO OVERHAULING .... AFTER THAT THE
MOTOR WILL BE COMPLETLY CHECKED FOR BEARING , GREASING ,
WINDING CONDITON BECUASE IT MIGHT BE OVERHEATED , TYPE OF
GREASE ,ROTOR , FAN , COUPLING AND SO ON
| Is This Answer Correct ? | 17 Yes | 7 No |
Post New Answer View All Answers
Why ground terminal is used in pot meter 10k ohms
how we calculate the withstansing current capacity of wires&cables?
why the rotor current becomes in steady state during high slip region? please verify with equations.
what is sevice settings for mccb?How can be it setted?
Whether amorphous core transformer is commercialized or not:Name of company making amorphous core transformer and what are different rating?
how to flameproof electrical motor on the shaft?
In Generator How suction compression power and exhaust works ?
What kind of maintenance is conducted for Transformer
if we have a industrial load of 400 kilowatts with 415 volt AC then how much total harmonic distortion (thd%) should be acceptable for steady power system.
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker
We have Diesel generator of 200KW. fuel consumption is always same,even connected light load or full load. Is it right?
What is mean by hot and cold loop testing?
what is mean by ideal infinite bus? why it is required to consider in fault short circuit calculations?
Please elaborate th´evenin’s theorem?