Answer Posted / nandan bikash sarma
when we will use ac as the exitation the direction of the
magnetic field (NORTH AND SOUTH pole) will change as the
direction of the current changes This will effect the
voltage that we getting from the alternator.So we use a dc
magnetic field
| Is This Answer Correct ? | 6 Yes | 3 No |
Post New Answer View All Answers
How time response of the system is divided?
Why use the vcb at high transmission system ? Why can’t use acb?
I WANT HOW CALCULATE TO CABLE FOR WELDING PLANT ?
hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.
what is the transformer rush current?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)
how we sesign the transformer give some specifion regarding design of transformers
how to calculation increase power factor for single phase
How to calculate the copper in HT motors if KW, RPM & Voltage is given
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
what clearance required for 4.5 mva dry type transformer?
How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.