Answer Posted / nikhil
I think they would be asking to differentiate physically AC
and DC motor. Same question was asked to me also.
Answer:- DC motor have brushes so heat is generated in them
hence in a dc motor slots will be provided for the
ventilation and better cooling purpose.
Also on a AC motor there will be three wires going in
(either single or three phase) for electrical connection
whereas it is not the case with the DC motors.
| Is This Answer Correct ? | 4 Yes | 3 No |
Post New Answer View All Answers
Why do we require transformer with less specific weight if supply frequency is increased?
what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker
HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS
How to apply 'c' license and also explain what is difference between 'c' and 'b'license.i am also working in one of the private company.i have finished my diploma in 2014 .i have already finished in ITI electrician course.....
How to calculate mf when meter equipment and meter are connected
why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Define availability (operational)?
What is VSCF windelectrical system?
What is kirchoff ’s current law (kcl)?
HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION
how i chosse capacitor bank if my energy meter is 48 kvr? tell me capacitor bank chossen formula?
how will reduce the voltage. if 12volt/250ma transformer toreduce 6 volt
block diagram of 2 ups system connected in parallel mode?
technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"