There are a Transformer and an induction machine. Those two
have the same supply. For which device the load current
will be maximum? And why?
Answer Posted / shahulsnfa
the motor has max load current compare to that of
transformer b coz.. the motor consumes real power.. and the
transformer is only producing the working flux and its not
consuming.. hence the load current in the transformer is
because of core loss so it is minimum.
| Is This Answer Correct ? | 16 Yes | 3 No |
Post New Answer View All Answers
for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?
What are the limitations of Kirchoff's laws?
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
Explain and give examples about VCB?
What was your role in the silicon evaluation/product ramp? What tools did you use?
What is the exact formula for one weber of magnetic flux?
How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?
why ten delta testing is carried out on power transformer
What is resonant frequency?
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
What is open loop and control loop systems?
Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job
how many stairs have you climbed while you were coming
what are the range of memory address in plc for L&T lx7 4A
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.