Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why use the VCB at High Transmission System ? Why can't use
ACB? Pls explain the ans.

Answer Posted / g.ravikanth

vcb means "vaccume" at higher potential there is a chance
of ionization of air molecules but if it is vaccume there
is no chance at all for ionization.

Is This Answer Correct ?    31 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?

1958


Define what is difference between fuse and breaker?

1231


Explain dc generator with its types?

1165


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1935


operation of protection relay watchdog contact?

2457


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

2469


how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.

2436


WHAT IS MEANING OF Gg & Gg IN hrc FUSE

3340


Differnce between negative Pahse SequenceFunction and unbalance Function?

1790


what is data block in plc ? How the values of data block are written and read by hmi ? what is the difference between function and function block ?

3464


The power supplied to a 50mH inductor from a 120V, 60Hz source will be

4841


hi all i like to know vat is power plot in control systems also i want to know abt latest trends in electrical & electronics

2004


how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps

1310


i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.

1850


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1511