Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the effect if power factor is above 1 or unity.

Answer Posted / ramesh pachamal

Power = 1.734 x V x Ix cos@
Say the power factor is 1 unity.
P=1.734x400x1x1=698.2watts. This much power need to send
from Power statin to do some work. The energy meter will
read the unit as same for this value. But if the power
factor is less or more say 0.8
P-1.732x400x1x.8=554.24watts. This much watts only will
read the meter. Remaining amound send from power station
willnot in calculated and is in losses.Remaining around 150
watts loss in same work.Thats why EB insisting to maintain
unity instead of lagging or leading.

Is This Answer Correct ?    4 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?

1987


which protection function should measure RMS value of current&DFT value of current?

2087


What are the difference between CT/PT operated Meter and RRAMR Meter for HT/LT application?

2619


I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.

2902


What is dc current source?

1310


in a simple IDMT relay we use neutral point of ct for earth fault then what is the requirement of neutral ct and cbct?

2176


why impedance relay is used for medium transmission line protection

2342


how to control the speed to switched reluctance motor

1952


explain remenance . differentiate high remenance type ct & low remenance type ct

2143


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2725


Is MEN and RCD related to each other ?? IF yes then how??

1882


why the rotor current becomes in steady state during high slip region? please verify with equations.

2000


why the perameters of secondary circuit are more important then that of the primary circuit of induction motor?

1923


what are factors comes under relay setting (distance relay 7sa52) under OPEN DELTA VTs connection??

2567


we are going to install a solar PV site and how can we calculate PV Solar Panel Efficiency, can anybody tell me complete method for its calculation.

2136