Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Give two basic sprrd control scheme of DC shunt motor.

Answer Posted / sindhu

1. by using flux control method:in this method a rheostat is connected across the field wdg to control the field current.so by changing the current the flux produced by the field wdg can be changed, and since speed is inversely proportional to flux speed can be controlled
2.armature control method:
in this method a rheostat is connected across armature wdg.by varying the resistance the value of resistive drop(IaRa)can be varied,and since speed is directly propotional to Eb-IaRa the speed can be controlled

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If we have to find the inductance of a dc shunt motor then by giving dc supply or ac supply and what is the reason for it. (this example is from "to determine the transfer function of a dc shunt motor ")

1990


Define maximum demand?

1072


what is the common earth

1088


Refernce currents are to be generated using refernce cueernts how can this be done??

2004


What is the main cause of magnetism?

2092


how harmonics generated in induction furnance? how minimise it?

2009


Why in ESP Positive earthed

3085


how technical is calculated in 11kv line and lt line

2062


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1952


What is mean by hot and cold loop testing? What is the difference between them?

1125


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2285


What is safety of Ht panel

1662


What are the basic & Majour problems in UPS ?

2130


Why only sinusoidal ac voltages are generated?why not triangular or sawtooth?

2094


What is servo motor? what is its purpose?

2057