Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which grade of concrete is the strongest?
M20,M25,M30,M35 or M40?

Answer Posted / nagesh raj

M- 40 is strongest It depends upon the design mix, . M-40
means its strengthis 40n/mm2

Is This Answer Correct ?    68 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Where is the worlds longest elevator and how long is it?

1160


how can can column be corrected when the design is not safe ? is the increasing the clearcover a solution?

1624


please give the detail design for the soring and shuttering for 8.5m deep excavation in the sandy soil for 25x10 rectangular streaches

2574


List out some of the software program that can be useful for architect?

1118


Would you cause a 55-gallon drum of water to weigh more by climbing in?

1133


What sizes of stones chips are used for foundation, column and floor casting. Please answer in detail.

2101


Why Should Curing Not Be Done By Ponding And Polythene Sheets?

1296


can we find any technical issue if we are gong to change the dimensions of steel beams from one type to another type IE if there are any equievelant data base to find solution for problem of changeing sectios of beam from one type to another with the same cross sectional area.

2053


can you mail me detailed procedure,entire syllabus and practice papers of mpsc civil engineering branch.I am in third year now

2167


In a beam,stirrups are placed closely at ends than at centre due to shear.similarly where would ties be closer to each other-at center or at ends in a column and slab.

3325


Calculation of curtain wall of box culvert

6107


What are the responsibilities of a construction manager?

1308


Define What is made from large rocks, which protects the base of cliffs?

1080


how to do cementicious paint for rcc walls of cw pump house

2036


The building has 12 columns of 12x9 in 3 rows of 4 each in a plot of 50'x30', The central row is strengthened with 16mm twisted rods. The roof area is 1500 sft including balconies. calculate the load factor per sft. Also indicate the number of roofs the building can withstand.