Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why dc supply is given to the field of alternator

Answer Posted / sanjay kumar

the reason why ac is not given to the excitation of field
of alternator lies behind the concept of mutual
induction.if ac field'll be given again the problem starts
when field current will rise and leads to deexcite
itself.hence it will not give uniform excitation like dc
current.

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

2067


we use capister for power factor. when we use capaciter in dg circuit  than defect dg. can we use capaciter bank for dg circuit

1928


what is the efficiency of thyristor

1648


Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?

4404


derive DC RMS value for half wave rectifier?

3214


What is the abbreviation of NGT panel

2044


can we use trip light with bus coupler?

1946


What is inductance?

1201


what is the effect of higher value of GD???

1797


I want to know Electrical Circuit?

2170


what is charger supervision and control supervision?

2076


I NEED RRB APTITUDE QUESTIONS AND MODEL PAPER,PLEASE SEND MY E-MAIL joo28_eee@yahoo.co.in

1928


A 3 phase transformer's (Y-Y) Y and B phase is (Y and B connection not broken) broken from neutral and R and Nutral connection is ok, what will be the relay tripping and why

1973


why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?

2079


what is the max. acceptable leakage current in 33kv bus bar

3020