WHERE IS THE LIGHTING ARRESTER SHOULD BE PLACED IN
DISTRIBUTION LINES?
Answer Posted / s.l.manohar
near distribution transformers and out going feedrs of 11kv
and incomming feeder of 33kv and near power transformers in
sub-stations
Is This Answer Correct ? | 80 Yes | 12 No |
Post New Answer View All Answers
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?
electromechanical relay type identification example : type=tjmh t-stants for j- m- h-
how braking & making capacity of circuit breaker is calculated?
how to set relay setting? and example calculation...
whats the differece between Exd and Exe
what happen if generator of micro hydro running at only a small percentage of its capacity, as a comparison, if the diesel generator that runs on only a fraction of its capacity there will be a wet stacking
what is the meaning of impedance protected in instrument cooling fan
we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
what is vA rating and class of a ct.
Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?
what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable
What is the maximum No. of out going mccbs permitted from an LV distribution paqnel? What is the ampere relation between incomer and out going switch gears/mccbs?
HOW WE CALCULATE CURRENT IF THERE ARE NOT PRESENT ANY AMMETER OR MULTIMMETER??????