a bulb of 100W and anather bulb of 200W , rated supply
voltage 230v.when supply voltage is reduced to 100v,which
bulb will give more light? and why with calculation?
Answer Posted / nitin
p=v^2/r
now in both cases whtevr the voltage ,it is same for both
bulbs.
now the main culprit is r,the bulb which has more
resistance would glow dimmer as per above formula.
we have used the above formula bcaz ,elctrcl instruments
are designd for constant voltage.
as power is inversely proportonal to the resistance (above
formula)therefor 200w bulb would have less resistance and
glow more
Is This Answer Correct ? | 13 Yes | 6 No |
Post New Answer View All Answers
What is the formula to calculate the size of Aluminium and copper cable?
What is accuracy of a measurement?
in an electronic tri vector meter when the current and voltage sequence changes ? what is the effect of phase sequence on recording of meter
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
What is a difference between indoor transformer and outdoor transformer of same rating
what are the steps involved in generator load test?
When we connect the large capacitor bank in series ?
hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.
give single line diagram of D.G distribution form alternator to main L.T panel?
any application of back emf
Why line VTG = √3 phase VTG in star? How?
how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters
Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
What is the formula for calculating impedance of transformers connected parallel at fault level 50KA?
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.