Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why all voltage levels are the multiples of 11KV?

Answer Posted / johince

Multiples of 11 has no role decoded from form factor and
anything like that (I believe). the relation to form factor
is just a coincidence.
In early days when technology has not advanced this much,
the transmission lines consumes around 10% of the total
power transferred. Normally loads are designed as multiples
of 10 or 100 KW. So the generation done for required load
power + transmission loss. ie 11KW, 110KW etc. So generated
voltage also was designed as multiples of 11.
Hence the insulators has to be designed for these volatges
and hence the form factor coincidently derived as 1.11.

Is This Answer Correct ?    35 Yes 56 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain what is rated speed?

1131


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2473


what are the assumptions made in swineburne's test?

2163


Differentiate between low pass, high pass and band pass filter?

1062


WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.

2657


I HAVE A 50A MCCB AS PER DESIGN LINE WIRE CONNECT UPWORD SIDE AND LOAD IS CONNECTED TO DOWNWARD SIDE TO THE MCCB.IF NOW ANY ONE CHANGE SUPPLY & LOAD(WISEVERSA) WHAT HAPPENS ? DOES MCCB OPERATION OR WORKING FUNCTION NORMAL IF YES THAN WHY THERE ARE MARKED LINE & LOAD ON MCCB.

2374


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1937


Please tell me the power flow from pmg to main rotor of an alternator (Including AVR unit)?

2023


Define sensitivity?

1089


Cb closed condition if there is a tcs fail whether cb will trip or not

1822


what is solkor relay and which condition it will act?

3352


how to calculate energy of 3-phase motor?

2064


What is marx circuit?

1119


why we use Test Terminal Block in 11 KV and 33 KV electrical panels.

1365


Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.