why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11
Answer Posted / johince
Multiples of 11 has no role decoded from form factor and anything
like that (I believe). the relation to form factor is just a
coincidence.
In early days when technology has not advanced this much, the
transmission lines consumes around 10% of the total power
transferred. Normally loads are designed as multiples of 10 or
100 KW. So the generation done for required load power +
transmission loss. ie 11KW, 110KW etc. So generated voltage also
was designed as multiples of 11.
Hence the insulators has to be designed for these volatges and
hence the form factor coincidently derived as 1.11.
| Is This Answer Correct ? | 27 Yes | 13 No |
Post New Answer View All Answers
Load break swicth maintenance procedure.
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
What is the principle of HIGH SPEED DIRECT DRIVE MOTOR ?
List the advantages of star-delta starter with induction motor?
If Polarization index of motor 8.75 at 500volts of medium voltage 4.16 KV motor what this mean winding good or bad pl answer if any reffrence book give me the link
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?
what do u understand about FACTS? how they are useful?
I don't understand why when we connect high voltage source in DC to electronic motor , we must add capacitor and resistor in parallel ? (I know that we use capacitor because we want to absorb the current that in the first second electronic motor in opposed with current course produce. ) what are the feature of Resistor and in such situation ?
what are the preventive maintanance actions taken for air circuit breaker? please answer me
which stabilizer is better ? AVR, Servo Stabilizer, Static stabilizer etc & why explain it
-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.
what are symmetrical and non symmetrical components in electrical installation.
why impedance relay is used for medium transmission line protection
Define liftable weight of a transformer? Does the total weight of transformer include oil weight?
how freewheeling diode improves the powerfactor