what is full form of lv and mv? 2.while we connect
capacitor to generator what will cause for it?

Answer Posted / siddu

connecting capacitor bank across the generator will disturb
the stability of generator operation because of uncntrol
reactive power components.normally this is not advisiable

Is This Answer Correct ?    12 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

xfhnchncv?

1416


What are the significant parts of dc generator?

646


In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.

1593


When is lag lead compensator is required?

640


What are the basic properties of signal flow graph?

696






How to measure the Harmonic Distortion of UPS ie THD?

1745


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1269


11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??

1200


Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.

533


what happened when we supply a dc current in dc motor?? can it worked properly?

1468


Can i replace Earth leakage relay to the faulty Earth Faulty Relay

1049


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

1497


1.why we are using metal oxide gapless block in lightning arrester,2.What is minimum and maximum rating of metal oxide blocks using in india

1526


please send me the L&T Emb. sys. placement papers and entire details of pattren

1854


11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1214