Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT ARE MAIN DIFFERENCE BETWEEN DCS AND SCADA?

Answer Posted / rafiq

dcs is nothing but distributed control system. i.e we are
distributing the control system
scada is nothing but supervisory control and data
acquisition. i.e it gathers the data from the process and
decides after that sends an response to the controller

Is This Answer Correct ?    51 Yes 26 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.

2082


What is cut off relay? And why use in PLC and DCS?

1373


The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?

2278


Describe the function of Accumulator into the Pump

1928


what is the process for double acting cylinder pneumatic for 32' v/v

2072


key exchanges in wpa,wpa2,tls

1924


how will you segregate the alarm levels in alarm management system during factory Acceptance Test

2386


Full form of KKS when use DCS.

3154


What is Span Error

690


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2452


what is output of FOUNDATION FIELD BUS transmitter

2145


i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure

1916


I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration  So is there any causes biside this or  any  permissives ?

1853


Identification of ss fittings, pilot valves, relief valve.

1828


how to calibrate and troubleshooting of leveltroll?

2186