What is the difference between HMI,SCADA and MMI,not
abbrevation?
Answer Posted / rajesh j
HMI and MMI denotes devices, but SCADA refers only
software, which can loaded in any computer.
HMI and MMI are one and the same (H-Human and M-Man). Both
gives same meaning. It depends on supplier nomenclature.
But SCADA is an advanced version of this (Its like
difference between MS dos and Unix).
In SCADA, data history can be provided whereas it is
generally not possible to get in MMI or HMI.
HMI and MMI are cheaper and more suitable for small
applications compared to SCADA.
| Is This Answer Correct ? | 55 Yes | 18 No |
Post New Answer View All Answers
how to calculate control valve bonnet size?? or how to select its material?
How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Isometric drawings are generated during _________________ phase of a project
i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?
what are the use of belew gear in general ??
How to calibrate H2s Dectector
Derive capacitance to 4-20ma conversion formula / relation in capacitance type pressure sensor?
State some of balance principle’ advantages?
Which language of programing is popular? how can i learn it ?
WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?
What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
How RAL(Rotary air lock)works in cement industry?
NSV type probe stands for