For a centrifugal pump if the pump is running and we close
the discharge valve what is the effect
Answer Posted / magx
You can run a centrifugal pump at shut-off head for sometime
say 5-10 minutes but further running may increase the
temperature of the fluid due to churning and can cause
failure of gaskets and lube oil faiukre
| Is This Answer Correct ? | 75 Yes | 6 No |
Post New Answer View All Answers
Given, T1=600C, constant temperature of wall 800 , length of wit exchanger L=3m, dia=25 mm, Cp=14.91 KJ/kg.K, density ρ=914 kg/m3,mean velocity vm= 2 m/s, film heat transfer coefficient hf=72 Kcal/h.m2.K, what is the outlet temperature?
Under what circumstances are vortex flowmeters the most accurate?
I am a Diploma Chemical Engineer by Nirma Uni; and BEng (Hons) Energy & Environmental Engineer by Napier Uni; Edinburg, UK. HPCL chemical engineering test will held on 14th July,09. So, Please send me some previous chemical engineering papers Objective types Or material to give the test.
I would like to know how to size a partial combustion reactor processing methane and oxygen, as a function of the flowrate and of the pressure.
What are the assumptions made on conservation equation?
What is a good method of analyzing powders for composition?
wha is Adsorption column chromatography?
Define an additive?
Are you having any experience in antibody designing?
The process conditions of the fuel gas are as follows: Temperature = 25 deg C Pressure = 4 bar g Calculate the line size for the fuel gas supply line to the superheater
Explain what is a good way to get started in doing a plant-wide steam consumption analysis?
What is the procedure to estimate the friction factor involved in heat exchanger tubes?
What is difference between overall heat transfer coefficient & individual heat transfer coefficient?
Explain some good strategies for curing tube vibration in shell and tube exchangers?
What are the advantages and disadvantages of using gear pumps?