deference between DCS and PLC including date processing and
architacture.
Answer Posted / rohan garibe
PLC is a programmable logic controller, which is a
centralised system. It only helps in implementing a
pre-defined and stored logic program in its memory.
DCS is Distributed Control System. As its name implies, it
is a system whose control functions are distributed
geographically and functionally over a large area. It has a
great coverage in industry.
| Is This Answer Correct ? | 26 Yes | 1 No |
Post New Answer View All Answers
why we are using magnet for calibration of gas detector?
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
how many type conductivity sensor ?
How to fix back the valve actuator stem
Identification of control valve parts.
what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?
Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.
Explain the difference between mmwc and mmwg?
How would you choose differential range?
There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?
In apron feeder how TPH is calculated?
what is the calibration procedure for transweigh make weigh feeder?
What is loop1 and loop2 in MTS LT?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what is the procedure of belt scale calibration?