why 4 to 20 ma ,why not 0 to 20 or 3 to 15 or anything
Answer Posted / naren
1. to obtain live zero
2. noise reduction
3. no current drop
4. longb tranmission
| Is This Answer Correct ? | 45 Yes | 13 No |
Post New Answer View All Answers
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
How to convert Differential pressure to flow in TPH
all questions related to instrument technician in any offshore oil and gas company.
-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.
Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?
What are different types of valves?
Why ac supply load cell is used? Can we use the dc supply load cell?
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies
What is voltage regulator?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
Where Can i take a SPI INtools training in Mumbai? In Rolta India Ltd to whom I should approach regarding of SPI INtools Training?