what is reset windup in integral control?
Answer Posted / welcome4ujd
By adding the reset action to the proportional action the
controller produces a larger output for the given error
signal and causes a greater adjustment of the
control valve. This causes the process to come
back to the setpoint more quickly. Additionally,
the reset action acts to eliminate the offset error
after a period of time. Reset Windup Proportional plus
reset controllers act to eliminate the offset error found
in proportional control by continuing to change the output
after the proportional action is completed and by returning
the controlled variable to the setpoint. An inherent
disadvantage to proportional plus reset controllers
is the possible adverse effects caused by large
error signals. The large error can be caused by
a large demand deviation or when initially starting up
the system. This is a problem because a large sustained
error signal will eventually cause the controller to drive
to its limit, and the result is called "reset windup."
Because of reset windup, this control mode is not well-
suited for processes that are frequently shut down and
started up.
| Is This Answer Correct ? | 24 Yes | 5 No |
Post New Answer View All Answers
what is diffrance between FF & SMART, explain with difination
Why rdt and thermocouple both give different output .and one things more, how to generate ohm or mili volt plz mail me merajalam143545@yahoo.com
Is there any relation between Artificial Intelligence and Instrumentation?
Can anyone send most commonley asked Instrumentation questions and answers in cement industry please?
how to commission furnace ( water heater)
send me HPCL paper
How to calibrate level transmitter with use of HART?
What is offset in a control system.
i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in
Area classification, Equipments, Gas groups, temperature classification, Ingress protection, Fire Extinguishers.
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
Calibration procedure for water rotameters
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744