Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE DIFFERENCE B/WDYNAMO&ALTERNATOR?

Answer Posted / kalaianbu

In practical there is no dc generator.Induced emf in an
any generator is always ac,but by using commutator we are
converting ac in to unidirectional supply.So the dynamo is
an electrical equipment which consists of commutator and it
gives unidirectional curent[not perfect DC]. The another
name of the dynamo is called as DC GENERATOR.
Alternator is an electrical equipment which dont have
commutator arrangement and it gives ac supply.

the names independent of the size .

Is This Answer Correct ?    41 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

use of choke in APFC panels

5826


What are the properties of a resistor?

1113


what is difference between 2 pole structure and 4 pole structure in transformer yard

6063


how we do Vector group ,magnetic balance and tap changer test in Transformer?

2473


What are the criteria shall be considers for sizing Fuse and MCB? If the rated current is 10Amps what should be the fuse size / MCB Size?

1639


Mention how NPN and PNP transistor works?

1290


Why do not we prefer non conventional sources of energy to conventional sources?

1203


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9237


what is ic 01,ic 06 ?is it types of cooling?

4321


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

1999


What is the implications when 600 hp motor is started when the unit is running with Transformer of capacity 1500 KVA and DG set of 1000kva

2219


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1930


how you will decide the distance between the power transformer and its fencing

1976


what the function breaker failure scheme, how is it operated

1908


How to calculate no of EARTH PIT? Describe the formula as per IS standard?

3848