Why we are using Ohm's law? where it is applicable? explain.
Answer Posted / electrical engineer
Ohm's Law defines the relationships between (V) voltage,
(I) current, and (R) resistance.
V=IR.
So if you know the value two of the variables in the
equation, you can then determine the third.
Also the (P) Power can be determined.
Ohm's law is used in the analysis of electrical circuits.
Ohm's law can be applied to a complete circuit or part of
the circuit provided V, I & R relate to the same part.
| Is This Answer Correct ? | 16 Yes | 2 No |
Post New Answer View All Answers
Write a note on Treatment for electric shock.
What is the meaning of HT Trivector Meter ?
how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc
define hysteresis loss, eddy current loss and windage loss
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
How i can calculate current of cable according to ares?
we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input
The ripple frequency in output of fullwave bridge rectifier is a. Half the input b. Twice the input c. Same as input
What does the term power factor shows?
we have a rewind motor of 2Hp,2800Rpm, 220Volt AC. how can we choose the running capacitor for this motor, any formula for that?
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
what is the id1 & id2 setting in differential protection relay of CSPC?
how to modify DOL control panel into Delta Y connection?
what is the maintaining Cf in UPS.
how to select battery for 15 KVA UPS with formula