Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How transformer winding & oil gets heat.

Answer Posted / uzy

whenever current flows through a wire there are i2rt losses
which r dissipated through resistors in the form of heat
also transformer has no moving part so all the
losses(unusable energy) in copper winding are evolving
through wires.
moreover the construction of transformer is closed type so
the heating becomes more.
since the oil tank is linked to the windings , as the
windings
heatup the oil filled in tank get heated and expands.

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If a high resistance fault occurs,then what are the changes will happen in the system?

1452


How to calculate the copper in HT motors if KW, RPM & Voltage is given

3198


Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.

1808


1. How many types of mangers? 2.How many types of capacitors? 3.pls tell me normally types alternator problems?

2325


is it possible to have dc motors on single chip

1831


What should be the voltage between Neutral and Ground in secondary side of the step down transformer (230 V to 110 V) with no load condition?

2030


1 Ton is equal to how many watts?

1095


please tell me how a surge protector work on a DC 48Volt.? please describe briefly.

1828


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2473


current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer

1592


What is force on parallel conductors ?

1073


what is the diff. between x'mer , isolation x'mer & ultra-isolation x'mer ?????????????

2333


What is the difference between security constraint unit commitment and security constraint optimal power flow?

1707


what is zinc diffusion?

2086


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1976