Answer Posted / suresh kumar
sir, iam suresh and i had completed my diploma in chemical
engineering in 2006. i want to write hpcl exam, please send
me previous papers.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
Why are the uses 24vdc in industries
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
What is the use of single seated valve?
how to calculate signal cable sizing? and multipair cable sizing??explain in brief?
What is zone,loop/fire alarm system?
what is The specifications for oriface instalation
how pressurize drum calibrated ?
How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?
field bus transmitter calibration procedure tell me