WHAT IS THE DIFFERENCE B/WDYNAMO&ALTERNATOR?
Answer Posted / ranga
A dynamo is a small size dc generator which varies with
load whereas an alternator is a synchronous generator
having a constant speed of rotation independent of load.
| Is This Answer Correct ? | 23 Yes | 0 No |
Post New Answer View All Answers
i want to model paper for section engg.
What are the reasons for the parallel operation of transformers?
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
how we provide neutral earth on synchronising panel as per electrical standards?
How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?
The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is
What are the types of instrument transformer?
how does the terminal voltage of transmission lines increase when a capacitor is connected???? This happens not only in transmission lines but also in all circuits. How??? When a capacitor is connected in a transmission line, capacitor also takes energy from the same supply. But how is it able to increase the terminal voltage??? Practically What sequence of events happen during increase in voltage???
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
briefly explain principle of resistance welding
Why syn. Generators are used for the production of electricity?
Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv
If UG power cable both ends are to be earthed or what? If not why?
Will an earth leakage trip be activated if the component or wiring is faulty on low voltage equipment.Example An electrical Cat Scarer placed in the garden and water gets into the wiring.
Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??