1> what r different types of fault in cables? How will u
locate and test these faults?
2> why earth wire is provided on top throughout the
transmission line. why not only on towers? How much area it
can protect?
3> what r different types of transmission losses? How power
loss can be minimized?
4> what is the % of power loss on transmission lines?
Answer Posted / akhil
1)i think that line to line faults happen in cables.by
noting the variation in current reading we can locate the
faults.
2) to save insulators and also to make insulators effective
between line and ground.
to save cost ,as providing earthing(coal & salt) to
particular tower for huge current is costly.
also huge current (in case of short circuit)can charged the
surrounding area.
how much area it can protect ? elabrote
3) refer some book
4) 8-10%
| Is This Answer Correct ? | 5 Yes | 17 No |
Post New Answer View All Answers
List few applications of d.c series motor?
im electrical engineer, could any one help me for FEWA exam questions please ?
There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2
What is the emf equation of a transformer?
Why does the speed regulating system adopting I controller have no steady-state error? In this single closed-loop speed regulating system, when the input of the I controller Un=0, what is the output voltage of the regulator? What factors do the output voltage depend on?
how the inner and outer body is separated in aircrafts?
In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?
how to differentiate a mpcb,mcb with a contactor? Explain their working operation
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
Define liftable weight of a transformer? Does the total weight of transformer include oil weight?
Hello sir, pls send me hpcl technical test papers .i am. Appearing for the exam.
what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?
how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???